VMB300I

VMB300I 100X-400X Binocular Inverted Biological Microscope with Infinity Optical System

227 x 208mm stage, glass rotundity Ф118mm, four different hight culture dish optional

Core Features
  • With wide field eyepieces, infinity and long working distance plan achromatic objectives, turn out or into condenser, the field of view is widely and clear
  • Coaxial coarse/fine focus system, with tensional adjustable and up stop, minimum division of fine focusing: 2μm
  • Coaxial high-strength steel wire mechanical stage driver
  • 6V 30W Halogen lamp with brightness control
Configurations
WF 10X (Φ20mm)
Binocular, inclined 45°
Quintuple
227mm x 208mm
6V 30W Halogen
VMB300I 100X-400X Binocular Inverted Biological Microscope with Infinity Optical System

VMB300I Inverted biological microscope is equipped excellent UIS optical system including long working distance plan achromatic objective and wide field plan eyepieces. Compact and steady main fram body is embodiment for the shock resistance. The enable turning out or into condenser system is suited for observation in a high culture dish. The ideal ergonomic desigm is adopted in ths unit and have easier operation and wider space. This is ideal optical instrument for micro observation in celltissue and transmitted liquid tissue, even in dynamic observation in the culture dish tissue. It can be used in scientific research, universities, medical treatment, epidemic prevention, agriculture etc.

The gemel mode binocular is inclined 45°. The operator cervix and shoulder are released from tired in period of time keeping bow or head-up. The eyepiece field of view number is Φ20mm and eyepath can be added.

It is possible for process visualization in turning nosepiece. Overcome the deficiencies of the stage thermal deformation effecetively.,

The mechanical stage driver is adopted coaxial high-strength steel wire. This is a ideal design for stable mobile. The automatic protection in the limited position is effective on the accuracy of stage. There are three mode culture dish holder for selection.

Integrated illumination can make up the difference of halogens by adjusting the spacial position. Fully taken into account the cooling effect of illumination system so that the surface tenperature of lamp house is lower, the operation is safer. Simpler and quicker way to replace the bulb without any tools. The enable turning out or into condenser system is suited for tissue observation in a high culture dish.

Equip high quality phase contrast plan objective and phase contrast condenser. There are two mode phase contrast condenser: turnplate.

The photographic observation output is setting up on the back of main body frame, so that the accessories of camera don’t cause interference to eyepiece observation. Microphotography in 100% light flux, suits for low illuminance microphotography.

VMB300I

Head & Mechanical Stage of VMB300I

Illumination System & Condenser System of VMB300I

Diagram of VMB300I

Dimension of VMB300I

Digital Camera Photo:

Bright & Positive Phase Contrast & Negative Phase Contrast Observe